Version 4 SHEET 1 1696 1164 WIRE 48 592 48 560 WIRE 48 480 48 448 WIRE 48 96 48 64 WIRE 48 -16 48 -48 WIRE 704 592 704 560 WIRE 704 480 704 448 WIRE 992 592 992 560 WIRE 992 480 992 448 WIRE 1264 592 1264 560 WIRE 1264 480 1264 448 WIRE 384 592 384 560 WIRE 384 480 384 448 FLAG 48 592 0 FLAG 48 448 v4 FLAG 48 96 0 FLAG 48 -48 v3 FLAG 704 592 0 FLAG 704 448 v5 FLAG 992 592 0 FLAG 992 448 v6 FLAG 1264 592 0 FLAG 1264 448 v7 FLAG 384 592 0 FLAG 384 448 v8 SYMBOL voltage 48 464 R0 SYMATTR InstName V4 SYMATTR Value PWL file=pwl4.txt SYMBOL voltage 48 -32 R0 WINDOW 3 -74 184 Left 0 SYMATTR Value PWL (0 0 +1u 1 +2u 0 +1u 1 +1u 0 +1u 1) SYMATTR InstName V3 SYMBOL voltage 704 464 R0 SYMATTR InstName V5 SYMATTR Value PWL file=pwl5.txt SYMBOL voltage 992 464 R0 SYMATTR InstName V6 SYMATTR Value PWL file=pwl6.txt SYMBOL voltage 1264 464 R0 SYMATTR InstName V7 SYMATTR Value PWL file=pwl7.txt SYMBOL voltage 384 464 R0 SYMATTR InstName V8 SYMATTR Value PWL file=pwl8.txt TEXT 24 -216 Left 0 !.tran 10u TEXT 1264 688 Left 0 ;(0 0 \n+ +1u 1 \n+ +2u 0 \n+ +1u 1 \n+ +1u 0 \n+ +1u 1) TEXT 376 680 Left 0 ;(0 0 \n+ 1u 1 \n+ 2u 0 \n+ 1u 1 \n+ 1u 0 \n+ 1u 1) TEXT -72 672 Left 0 ;(0 0 +1u 1 +2u 0 +1u 1 +1u 0 +1u 1) TEXT 680 680 Left 0 ;(0 0 \n+1u 1 \n+2u 0 \n+1u 1 \n+1u 0 \n+1u 1) TEXT 976 688 Left 0 ;(0 0 \n++1u 1 \n++2u 0 \n++1u 1 \n++1u 0 \n++1u 1) TEXT 968 -96 Left 0 ;.include pwl1.txt TEXT 976 -40 Left 0 ;V1 v1 0 PWL(0 0 \n+1u 1 \n+2u 0 \n+1u 1 \n+1u 0 \n+1u 1) TEXT -88 -752 Left 0 ;PWL With Relative Time Settings\nHelmut Sennewald 8/16/2004\nRequires LTSPICE version 2.11a or newer.\n \nIf the time value in a PWL statement is preceeded by a + , \nthen it is assumed that this time value is relative to the previous time.\nThese examples should show the allowed cases for relative time\nsettings of PWL with netlist type PWL and PWL file=name types.\nHint: The comment below the examples is the content of the \nPWL data file. TEXT 472 -104 Left 0 !.include pwl2.txt TEXT 480 -56 Left 0 ;V2 v2 0 PWL(0 0 \n+ +1u 1 \n+ +2u 0 \n+ +1u 1 \n+ +1u 0 \n+ +1u 1) TEXT 968 -176 Left 0 ;PWL time voltage pairs out of chronological\norder in source V1. 2e-6 is not before 1e-6 TEXT 936 -320 Left 0 ;WRONG relative time values!\n+ is treated as line continuation in netlist\nand not as relative time operator for PWL. TEXT 480 -256 Left 0 ;This is correct.\nThe first + is line continuation \nand the second + forces\nrelative time for PWL.\n++ and + + is ok here. TEXT -56 -400 Left 0 ;NETLIST TYPE PWL PWL(....) TEXT -64 312 Left 0 ;Real PWL FILE TYPE PWL file=name LINE Normal 1416 -376 888 152 LINE Normal 1416 152 888 -376 RECTANGLE Normal 1504 208 -96 -448 RECTANGLE Normal 1504 880 -96 272