Version 4 SHEET 1 1180 680 WIRE -240 256 -240 208 WIRE -240 400 -240 336 WIRE -192 208 -240 208 WIRE 16 304 16 288 WIRE 16 400 16 384 WIRE 32 176 32 32 WIRE 64 32 32 32 WIRE 80 176 32 176 WIRE 80 208 -112 208 WIRE 112 160 112 144 WIRE 112 304 112 224 WIRE 112 400 112 384 WIRE 176 32 144 32 WIRE 176 192 144 192 WIRE 176 192 176 32 WIRE 224 192 176 192 FLAG -240 400 0 FLAG 16 400 0 FLAG 112 400 0 FLAG 16 288 +5V FLAG 112 144 +5V FLAG 224 192 out FLAG -240 208 in SYMBOL Opamps\\1pole 112 192 R0 SYMATTR InstName U1 SYMATTR SpiceLine2 en=10n enk=0 in=1p ink=0 Rin=500Meg SYMBOL res 48 48 R270 WINDOW 0 32 56 VTop 0 WINDOW 3 0 56 VBottom 0 SYMATTR InstName R1 SYMATTR Value 2k SYMBOL res -208 224 R270 WINDOW 0 32 56 VTop 0 WINDOW 3 0 56 VBottom 0 SYMATTR InstName R2 SYMATTR Value 1k SYMBOL voltage 16 288 R0 SYMATTR InstName V1 SYMATTR Value 5 SYMBOL voltage 112 288 R0 SYMATTR InstName V2 SYMATTR Value -5 SYMBOL voltage -240 240 R0 WINDOW 123 0 0 Left 0 WINDOW 39 0 0 Left 0 SYMATTR InstName V0 SYMATTR Value SINE(0 1 10k) TEXT -296 -128 Left 0 !;noise V(out) V0 dec 100 1 1MEG TEXT -296 -48 Left 0 ;Right-click on the opamp to set the parameters TEXT -296 -88 Left 0 !.tran 5m TEXT -304 -256 Left 0 !.measure tran t1 FIND time WHEN V(out)=0.5 TD=500u RISE=1 TEXT -304 -224 Left 0 !.measure tran t2 FIND time WHEN V(out)=0.5 TD=500u RISE=11 TEXT -304 -192 Left 0 !.measure tran f0 PARAM 10/(t2-t1) TEXT -304 -320 Left 0 ;Measure the frequency of a signal with ".measure"-commands\nUse View->SPICE Error Log to look for the result.